PROFI pumping and water control units

PROFI pumping and water control units with integrated drinking water supply are used in large commercial systems with water reuse.

 

  • Double-pump system, with self-priming multistage horizontal centrifugal pump with frequency converters (optional) and alternating start-up
  • connection possibility of up to two feeder pumps for e.g. 2-cylinder operation
  • maximum volume flow up to 25 m³/h
  • electronic control with 4-line LCD display
  • operating hours counter for each pump
  • pressure display of the double pump system
  • level indicator of the collecting tank
  • manual switch-over to drinking water operation possible
  • stagnation circuit individually adjustable
  • potential-free fault indicator
  • RS 232 interface (ASCI II) for all common building management systems
  • everything mounted in a housing made of powder-coated sheet steel 

The INTEWA pumping and water control unit PROFI comprises an integrated receiver tank, a double-pump booster system with self-priming multistage horizontal centrifugal pump, an alternating start-up and the electronic control system - all mounted in a housing made of powder-coated sheet steel. The control system constantly monitors the levels in the collection tank and the receiver tank. It includes: 4-line LCD display, operating hours counter for each pump, pressure display of the double pump system, level display of the collecting tank, potential-free fault indicators, RS 232 interface for all common building management systems.

The INTEWA pump and water control units PROFI SC are additionally equipped with frequency converters. The frequency control makes the use of an additional diaphragm compensation tank unnecessary. The SC systems should always be used where long-lasting uniform pressure is required. This is the case, for example, in sprinkler systems with a predetermined throw of the water or cooling of buildings where the water is sprayed in the air conditioning system.

The feeder pump in the collection tank automatically delivers water to the supply tank of the pumping and water station as required. In the event of a water shortage or manual switchover, drinking water is automatically fed into the storage tank as required in accordance with DIN EN 1717. In addition, the solenoid valve is activated regularly to prevent stagnation in the drinking water line. The system is largely self-operating. Only a few manual operations and adjustments are necessary.

Charging pump

Connection set rainwater central

Connection set per feeder pump

Standard version16-6010-9016-9030-6030-80
Frequency controlledn/a10-90-SC16-90-SC30-60-SC30-80 SC
Flow rate max. (m³/h)149142525
Pressure max. (bar)5,899,25,98,4
Delivery head max. (m)5890925984

Current consumption max. A

(supply voltage V)

2x 6,2 (1x~230)2x 3,2 (3x~400)2x 3,8 (3x~400)2x 4,0 (3x~400)2x 6,4 (3x~400)
Motor power P1 max. (kW)2x 1,332x 1,462x 2,002x 2,212x 3,18
Protection classIP44IP44IP44IP44IP44
Free outletEN1717EN1717EN1717EN1717EN1717
Width (mm)570800800800800
Height (mm)1325-13351670-16901670-16901670-16901670-1690
Depth (mm)630725725725725
Weight empty (kg)100140150165165
Weight max. (kg)190310320335335
Pressure line connection1 ½ " AG1 ½ " AG1 ½ " AG2 " AG2 " AG
Connection feeder pump1 ¼ " AG1 ¼ " AG1 ¼ " AG2 " AG2 " AG
Number of feeder pumpsup to 2up to 2up to 2up to 2up to 2
Connection drinking water1 ¼ " AG1 ¼ " AG1 ¼ " AG1 ½ " AG1 ½ " AG
Volume of storage tank (l)100200200200200
Emergency overflowDN100DN100DN100DN100DN100
Level sensor* (m)5050505050
Cable level sensor (mm²)H03 VV-F 2G 0,75 H03 VV-F 2G 0,75 H03 VV-F 2G 0,75 H03 VV-F 2G 0,75 H03 VV-F 2G 0,75 
Cable connection feeder pump (mm²)H03 VV-F 2G 1,5H03 VV-F 2G 1,5H03 VV-F 2G 1,5H03 VV-F 2G 1,5H03 VV-F 2G 1,5
      

*no underground cable, factory extendable

 ZBP-14ZBP-36ZBP-46
Diameter [mm]160129129
Hight [m]474563643
Suction line1 ¼ " IG1 ¼ " IG1 ¼ " IG
Pressure line1 ¼ " IG1 ¼ " IG1 ¼ " IG
Supply line [cable]* [m]102020
Flow rate max.[m³/h]161616
Pressure max. [bar]102020
Plant height max. [m]13,513,513,5
Immersion depth max. [m]102020
Protection classIP68IP68IP68
Rated power [W]110020002100
Supply voltage [V/Hz]230 / 50230 / 50230 / 50
Weight [kg]111921

*no underground cable, factory extendable